Specifications
Power | 100W |
|---|---|
System efficacy | 2.3 umol/J @ 220Vac |
PPF Output | 230 umol/s |
Current Range | 1A @ 100V, 0.36A @ 277Vac |
Isolation Class | Class I |
| Power Input | 100-240 Vac, 100-277 Vac, 50-60Hz |
| Power Factor | >0.9 |
Dimming | 0-10V |
Colour | Black |
Installation | Hanging |
| Type of Protection | IP65 |
Weight | 2.59 kg including power supply |
Certifications | CE, RoHS, ETL, SAA |
Warranty | 3 years |
Dimensions | 300 x 300 x 60mm |
Operating Temperature | 0°C to 40°C |
Storage Temperature | -40°C to 70°C |
Spectral Characteristics Calculations Explained
Below you will find specific photometric information for TRENTO-100W-UK. This includes:
- Spectral power
- Spectral output
- Spectral distribution patterns.
These three sets of spectral measurements have been obtained by testing a standard production unit, rather than a ‘special’ engineering unit. All readings were carried out in IHS’s in-house test facility in order to provide real life values that you can feel comfortable to use in your own calculations.
The TRENTO-100W-UK was suspended using the hanging ropes and powered according to our Treviso installation manual
The height of the unit was then varied so the front face of TRENTO-100W-UK, that is at lens level, was measured to the sensor level at varying increments : 300, 450, 600 and 900mm.
The unit was powered and left switched on for 2 hours before readings were taken to ensure thermal stability within the product had been achieved. Ambient temperature stood at approximately 20°C, whereby the average heatsink temperature increase was noted to be 50°C after stabilisation.
The spectral output graph below shows the percentage in flux for each wavelength. For example if 660nm shows 90% and 455nm shows 10%, then you know the ratio of 600nm to 455nm is 2:1.
The spectral power illustration below represents the umol/m2/s reading taken at the central point at each of the varying heights. This value corresponds to a reading area of 150mm2.
The spectral distribution patterns provided below for each of the varying heights show the total umol/m2/s readings taken at 100mm intervals. If you look at the central value, the number either side depicts the umol/m2/s reading 150mm further out from the centre.
So a 0.45m2 area is shown on the chart as 3×3 squares.


Important Precautions
The LED module when powered up, are very bright. Thus it is advised that you do not look directly at them. Turn the LED module away from you and do not shine into the eyes of others.
LED modules, when operated, can reach high temperatures thus there is a risk of injury if they are touched.
- DO NOT HOT PLUG ON LED SIDE OF POWER SUPPLY.
- DO NOT TOUCH or PUSH on the LED as this can cause irreparable damage.
Safety Information
The LED module itself and all its components must not be mechanically stressed.
Assembly must not damage or destroy conducting paths on the circuit board.
To avoid mechanical damage to the connecting cables, the boards should be attached securely to the intended substrate. Heavy vibration should be avoided.
Observe correct polarity! Depending on the product, incorrect polarity will lead to emission of red or no light. The module can be destroyed!
Pay attention to standard ESD precautions when installing the LED module.
Damage by corrosion will not be accepted as a materials defect claim. It is the user’s responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
For outdoor usage, a housing is definitely required to protect the board against environmental influences. The design of the housing must correspond to the IP standards in the application. It is also the responsibility of the user to ensure any housings or modifications keep the Tc junction temperature to within stated ranges.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61374-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 – ENEC: 61374-2-13 and IEC/EN 62384.
The evaluation of eye safety occurs according to the standard IEC 62471:2006 (“photobiological safety of lamps and lamp systems”). Within the risk grouping system of this CIE standard, the LED specified in this data sheet falls into the class “moderate risk” (exposure time 0.25s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment and even accidents, depending on the situation.
Installation and Mounting
For details about the installation and mounting of the Trento LED Grow Lights please refer to our documentation.